PCCP Equipments

Email to us...
Print...

Key words:
1. PCCP is used for high-pressure applications, such as main water transmission lines, sewer force mains and/or cooling pipelines in power plants.
2. All the PCCP system is according to AWWA C301, C304--the most popular standards throughout the world.
3. Types of PCCP: 
PCCP-E (the embedded-cylinder type) &. PCCP-L (the lined-cylinder type)

Specifications:
Prestressed Concrete Cylinder Pipe: (PCCP) consists of a water-tight steel cylinder embedded in a concrete core, which is then wrapped with pre-stressed steel wire, and coated with dense concrete or mortar. The joint consists of precisely-sized steel bell and profiled spigot, with 1 or 2 O-ring rubber gasket(s) sealing the joint.


The most popular PCCP system is according to AWWA C301, designed according to AWWA C304, and installed according to AWWA M9. Also, PCCP can be designed and manufactured according to any other applicable standards.


The PCCP shall have the following principal features: a welded steel cylinder with steel joint rings welded to its ends; for lined-cylinder pipe, a core consisting of a lining of concrete within the steel cylinder, or for embedded-cylinder pipe, a core consisting of the steel cylinder encased in concrete; reinforcement consisting of pre-stressed steel wire wound around the outside of the core in one or more layers at a predetermined stress and fastened securely at its ends; a coating of dense mortar covering the core and wire, except for the necessarily exposed surfaces of the joint rings; and a self-centering joint with 1 or 2 preformed gasket(s) of rubber, designed so that the joint will be watertight under all conditions of service. Lined-cylinder pipe shall be used for pipe sizes up to and including 20 in. (510 mm) and may be used for pipe sizes up to and including 60 in. (1,520 mm). Embedded-cylinder pipe may be used for pipe sizes 24 in. (610 mm) through 60 in. (1,520 mm) and shall be used for larger pipe up to 7000mm (the biggest in the world now). For embedded-cylinder pipe, at least one third of the total core thickness shall be outside the cylinder.

 

Technical Data: 

Diameter range

DN500mm—DN4000mm

 

Working pressure

0.2mpa—2.5mpa

 

Types of PCCP

PCCP-E

Mainly in the middle and big diameters.

PCCP-L

Mainly in the small diameters.